| Type |
Type Designation |
| ..C.. |
Conducting metal casing over the stranded cores or between the inner and outer sheath (shield) |
| |
Additional information about the shield for the conductor cross-sections, e.g. 12×1 (C) which |
| (C) |
means 1 mm^2 individually shielded or 6×(2×1)C which means 2×1 mm^2 twisted and shielded |
| |
pairs |
| ...CE... |
Conducting metal casing over the insulation of the outer conductors |
| ...CG... |
Conducting non-metal casing over the stranded cores or between the inner and outer sheath (shield) |
| ..CGE... |
Conducting non-metal casing over the insulation of the outer conductors |
| FM |
Telecommunication lines within the cable |
| G |
Rubber compound |
| …K... |
Rubber cradle separator in the centre of the cable |
| KON |
Concentric protective conductor between the inner and outer sheath or concentric control/ monitoring conductor |
| LWL |
Fibre-optic (FO) |
| N |
Design according to the corresponding standard |
| (N) |
Based on a standard |
| -J |
Additional information about the type: with green/yellow marked core |
| -O |
Additional information about the type: without green/yellow marked core |
| "O |
Oil-resistant outer sheath (according to DIN VDE 0473, Part -2-1, Para. 10) (OE) |
| ...SH... |
Heavy tough rubber-sheathed flexible mining- type cable (Rough handling) |
| ...SHT... |
1 kV reeling cable |
| ...SL... |
Control cable |
| ST |
Control cores within the cable |
| ...T... |
Support element |
| ...TM... |
Trailing cable for medium mechanical stresses |
| ...TS... |
Trailing cable |
| U |
Flame-retardant outer sheath (according to DIN VDE 0472, Part 804) “non-inflammable“ |
| "UL |
Monitoring conductor within the cable (UEL) |
| ...W... |
Weather resistant |
| Y |
PVC compound |
| 2Y... |
Definition of the insulation material (2Y = PE) |
| /3 |
Protective-earth conductor uniformly distributed in the three interstices |
| /3E |
Protective-earth conductor uniformly distributed over the insulation of the outer conductor |
| ...3G... |
Definition of the insulating material (3G = EPR) |