KX Series Coaxial Cables 50 Ω/75 Ω
Applications
These radio frequency cables are suitable for high frequency data transmission (communication equipment, radar, instrumentation equipment) and video signal transmission.
Standards
- In line with MIL C17
- IEC 60092-359
- IEC 60332-3-22
- IEC 60754-1/2
- IEC 61034
Construction
| Conductors |
Solid or stranded CCS (Bare copper plated steel), BC (Bare copper). |
| Insulation |
PE. |
| Fire Barriers |
Aluminium foil. |
| Screen |
Single or double braid. Bare, tinned or silvered copper. |
| Outer Sheath |
LSOH (SHF1). |
Electrical Characteristics
| |
|
KX 3B |
KX 6A |
KX 8 |
| Characteristic Impedance |
Ω |
50 |
75 |
75 |
| Capacitance |
pF/m |
106 |
72 |
72 |
| Velocity |
% |
66 |
66 |
66 |
| Attenuation @200MHz |
dB/100m |
45 |
20 |
12 |
Mechanical and Thermal Properties
| Bending Radius for Fixed Installations |
10×OD |
| Temperature Range |
-30℃ ~ +60℃ |
Dimensions and Weight
50 Ω
| Part No. |
Cable Type |
Conductor Stranding |
Conductor Diameter |
Dielectric Diameter |
Nominal Overall Diameter |
Nominal Weight |
| |
|
No.×mm |
mm |
mm |
mm |
kg/km |
| MLN-KX3B |
KX 3B |
7×0.16 CCS |
0.48 |
1.50 |
2.55 |
10 |
75 Ω
| Part No. |
Cable Type |
Conductor Stranding |
Conductor Diameter |
Dielectric Diameter |
Nominal Overall Diameter |
Nominal Weight |
| No.×mm |
mm |
mm |
mm |
kg/km |
| MLN-KX6A |
KX 6A |
7×0.20 BC |
0.6 |
3.7 |
6.1 |
57 |
| MLN-KX8 |
KX 8 |
7×0.40 BC |
1.2 |
7.25 |
10.3 |
145 |